AbsoluteMove sent <Speed><PanTilt x="1" y="1"/><Zoom x="1"/></Speed>
with no space attribute. A device then reads the value in its own
default speed space (the one of the PTZConfiguration DefaultPTZSpeed),
where 1 isn't necessarily the maximum. On such cameras the ABS
moves were slower than the preset moves.
- pOnvif::ptz_GetNode() now parses SupportedPTZSpaces and keeps the
PanTiltSpeedSpace / ZoomSpeedSpace to use: the generic one if the node
lists it, otherwise the first one with its own XRange. Without GetNode
it falls back to GenericSpeedSpace / ZoomGenericSpeedSpace (0..1).
The debug printf of the whole reply is removed.
- ptz_AbsoluteMove() sends the speed with the space attribute, at the
space's maximum (optional speed argument 0..1 of the range).
- protocolPTZ_ONVIF::create() reads the node's speed spaces once and logs
which speed is used.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_0139veDo3XyavMuVhdnHcN16