#ifndef __PROTOCOL_SAFESHORE_HEADER__
|
|
#define __PROTOCOL_SAFESHORE_HEADER__
|
|
|
|
#ifdef __linux__
|
|
#include <features.h>
|
|
#endif
|
|
|
|
#include "protocolHTTP.h"
|
|
|
|
#include <time.h>
|
|
#include <stdio.h>
|
|
#include <stdlib.h>
|
|
#include <sys/types.h>
|
|
#include <sys/timeb.h>
|
|
#include <string>
|
|
|
|
#include "../../components/base/basicFunctionality.h"
|
|
#include "../../components/base/basicLogCollection.h"
|
|
#include "../../components/base/basicSettingsProvider.h"
|
|
|
|
#include "xmlParser.h"
|
|
|
|
#define PROTOCOL_TYPE_3D true
|
|
#define PROTOCOL_TYPE_2D false
|
|
|
|
#define SERVICE_URL_TEMPLATE_STATUS "/sensors/lidar%dd/%s/status"
|
|
#define SERVICE_URL_TEMPLATE_FAULT "/sensors/lidar%dd/%s/fault"
|
|
#define SERVICE_URL_TEMPLATE_EVENT "/sensors/lidar%dd/%s/event"
|
|
#define SERVICE_URL_TEMPLATE_CALLBACK "/sensors/lidar%dd/%s/httpcallback"
|
|
#define SERVICE_URL_TEMPLATE_CLOCKSYNC "/sensors/lidar%dd/%s/clocksync"
|
|
|
|
|
|
#define PACKAGE_ENVELOPE_TEMPLATE_STATUS "<lcu:SystemStatus xmlns:lcu=\"http://www.safeshore.eu/lcu/schema\">" \
|
|
"<lcu:Mode>%s</lcu:Mode>" \
|
|
"<lcu:Timestamp>%s</lcu:Timestamp>" \
|
|
"</lcu:SystemStatus>"
|
|
|
|
#define PACKAGE_ENVELOPE_TEMPLATE_FAULT "<lcu:FaultDescription xmlns:lcu=\"http://www.safeshore.eu/lcu/schema\">" \
|
|
"<lcu:Level>%s</lcu:Level>" \
|
|
"<lcu:Timestamp>%s</lcu:Timestamp>" \
|
|
"<lcu:Description>%s</lcu:Description>" \
|
|
"</lcu:FaultDescription>"
|
|
|
|
#define PACKAGE_ENVELOPE_TEMPLATE_EVT2D "<lcu:EventLidar2D xmlns:lcu=\"http://www.safeshore.eu/lcu/schema\">" \
|
|
"<lcu:UniqueId>%s</lcu:UniqueId>" \
|
|
"<lcu:Timestamp>%s</lcu:Timestamp>" \
|
|
"<lcu:Target><lcu:Id>%d</lcu:Id>" \
|
|
"<lcu:Coordinates><lcu:Azimuth>%d</lcu:Azimuth><lcu:Distance>%d</lcu:Distance></lcu:Coordinates>" \
|
|
"<lcu:Width>%d</lcu:Width></lcu:Target>" \
|
|
"</lcu:EventLidar2D>"
|
|
|
|
#define PACKAGE_ENVELOPE_TEMPLATE_EVT3D "<lcu:EventLidar3D xmlns:lcu=\"http://www.safeshore.eu/lcu/schema\">" \
|
|
"<lcu:UniqueId>%s</lcu:UniqueId>" \
|
|
"<lcu:Timestamp>%s</lcu:Timestamp>" \
|
|
"<lcu:Target><lcu:Id>%d</lcu:Id>" \
|
|
"<lcu:Coordinates><lcu:Azimuth>%d</lcu:Azimuth><lcu:Elevation>%d</lcu:Elevation><lcu:Distance>%d</lcu:Distance></lcu:Coordinates>" \
|
|
"</lcu:Target>" \
|
|
"</lcu:EventLidar3D>"
|
|
|
|
#define PACKAGE_ENVELOPE_TEMPLATE_REG_CALL "<lcu:Callback xmlns:lcu=\"http://www.safeshore.eu/lcu/schema\">" \
|
|
"<lcu:XAddr>%s</lcu:XAddr>" \
|
|
"</lcu:Callback>"
|
|
|
|
#define PACKAGE_ENVELOPE_TEMPLATE_CLOCKSYNC "<lcu:ClockSyncQuery xmlns:lcu=\"http://www.safeshore.eu/lcu/schema\">" \
|
|
"<lcu:t0>%s</lcu:t0>" \
|
|
"</lcu:ClockSyncQuery>"
|
|
|
|
#define OS_SCANNER_NAME_SIZE 128
|
|
#define OS_LCU_ADDRESS_SIZE 16
|
|
|
|
/**
|
|
* TODO: Add class description
|
|
*
|
|
* @author gagua
|
|
*/
|
|
class protocolSafeShore : public protocolHTTP {
|
|
private:
|
|
basicLogCollection *m_pLog;
|
|
config_setting_t *m_pSettings;
|
|
int m_nScannerDimentions;
|
|
CSTR m_pScannerName;
|
|
CSTR m_pServerIP;
|
|
int m_nServerPort;
|
|
bool m_bCurrentStatus;
|
|
CSTR buildURL( CSTR templ, int dim, CSTR devID );
|
|
CSTR buildUniqID( void );
|
|
bool buildClockSyncPackage( unsigned char *Buffer, int &BufferSize );
|
|
bool buildCallBackPackage( unsigned char *Buffer, int &BufferSize, CSTR CallBackPath );
|
|
bool buildStatusPackage( unsigned char *Buffer, int &BufferSize, bool Status );
|
|
bool buildFaultPackage( unsigned char *Buffer, int &BufferSize, unsigned char Type, CSTR Description );
|
|
bool buildEvent2DPackage( unsigned char *Buffer, int &BufferSize, CSTR msgUID, int targetID, int Angle, int Range, int Width );
|
|
bool buildEvent3DPackage( unsigned char *Buffer, int &BufferSize, CSTR msgUID, int targetID, int Angle1, int Angle2, int Range );
|
|
|
|
protected:
|
|
virtual bool packetHandler( protocolPackage *Package );
|
|
public:
|
|
// Constructor
|
|
explicit protocolSafeShore( config_setting_t *Settings = NULL );
|
|
//ToDo: change Serial to BaseClass of some kind of socket
|
|
//protocolSafeShore( clientPort *SocketTransport, config_setting_t *Settings = NULL );
|
|
// Destructor
|
|
virtual ~protocolSafeShore();
|
|
virtual bool init(){ return true; };
|
|
bool Alarm2D( int Angle, int Range, int Width, int ID=0 );
|
|
bool Alarm3D( int Angle1, int Angle2, int Range, int ID=0 );
|
|
bool VisibilityChanged( bool Worsened );
|
|
bool StatusUpdate( void );
|
|
void SetStatus( bool A ){ m_bCurrentStatus = A; };
|
|
bool ErrorReporting( int lvl, CSTR Descr );
|
|
bool StartTimeSynch( void );
|
|
#ifdef __linux__
|
|
//bool FinishTimeSynch( unsigned long long *tVals );
|
|
#else
|
|
//bool FinishTimeSynch( unsigned __int64 *tVals );
|
|
#endif
|
|
bool SetupCallBack( CSTR CallBackPath );
|
|
void setProtocolType( bool DeviceIs3D );
|
|
void setScannerName( CSTR Name );
|
|
};
|
|
|
|
#ifdef __linux__
|
|
unsigned long long getSHTimeValue( void );
|
|
#else
|
|
unsigned __int64 getSHTimeValue( void );
|
|
#endif
|
|
|
|
#endif
|